6 NC Machine Data (NC MD), NC Setting Data (NC SD)
6.12.1 NC setting data (NC SD)
R parameter assignment
R0
R49:
R50
R99:
R100 –
R199:
R200 –
R219:
R220 –
R239:
R240 –
R299:
R300:
R301 –
R499:
R500 –
R599:
R700 –
R999:
Note:
R parameter areas R100 to R199, R500 to R599 and R700 to R999 are provided for the user
as standard.
The user can also use the other R parameters if he is not using the associated functions
(CL 800 language, SIEMENS cycles or similar).
6–220
More user manuals on
Typical application per channel:
Input of cycles and subroutines.
Typical application per channel:
For calculations within cycles and subroutines. The same local parameters
may be used for nested subroutines. When cycles or subroutines are
called with @ 040 to 043, an R parameter stack saves the data used so
far and stores them after return to the calling program.
Typical application per channel:
Memory for data which must be accessible for the main programs and
subroutines. R100 to R109 are assigned if Siemens tool management is
used. R110 to R199 are free for the user.
Siemens assignment (cycle converter)
CL800 compiler on WS800 compiler (Siemens assignment)
Intended for internal assignment by Siemens as required
Stack pointer for @040, @041, @042, @043 (set to 301 with each M2,
M30 RESET)
Stack area for @040, @041, @042, @043
100 new global R parameters per channel
Use: as for R100 to R199
Typical application:
Higher-level memory for all NC channels, e.g. for buffering target positions
used by another channel.