Siemens SINUMERIK 840C Installation Instructions Manual page 546

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

09.95
20.0
dB
-60.0
180
Phase
Deg
-180
Note:
The value entered in MD 1516 (Numerator bandwidth speed setpoint filter 1) must not be
greater than twice the value set in MD 1515 (bandwidth speed setpoint filter 1).
1517
The description of this machine data is the same as that for machine data MD 1514!
1518
Input of 3dB bandwidth for speed setpoint filter 2 (band-stop). The filter is activated via
machine data MD 1500 (No. speed setpoint filters) and MD 1501 (Type speed setpoint filter).
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
5
5
Stop frequency speed setpoint filter 2
Default value
Lower input limit
3 500.0
Bandwidth speed setpoint filter 2
Default value
Lower input limit
500.0
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
Log Hz
Log Hz
Upper input limit
1.0
7 999.0
Upper input limit
5.0
7 999.0
6FC5197- AA50
7.3.2 Drive MD (data description)
fz
= 900 Hz
fbn = 1800 Hz (Dn = 100%)
fbz = 36 Hz (Dz = 2%)
fn
= 100%
4 k
4 k
Active
at once
Units
Hz
Active
at once
Units
Hz
7–131