09.95
BEASATZNR_FLAG_
DFLT
BAESATZNR_STEP_
DFLT
BAESATZNR_START_ The starting address is specified in BAESATZNR_START_DFLT.
DFLT
ICON 1–5
Mutual exclusion of applications depending on the capacity of the main memory
a 2 5 3
a 2 1 107
a 2 1 114
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
SINUMERIK 840C (IA)
More user manuals on
The parameters below contain the preset values for block generation.
The BEASATZNR_FLAG_DFLT word specifies the selection;
block number YES parameter = 1 or block number NO parameter = 0.
The value specified in BAESATZNR_STEP_DFLT defines the block
number steps.
These values can be changed temporarily in the ASCII editor. After power on,
however, the preset values are valid.
If an MMC CPU with 16 MB is used, the following line must be inserted in Bed-
conf file (in the user branch) unless it already exists:
l 1 2 16000 1 // Change to 1 only when MMC-CPU with 16 MB RAM L
Three icon fields underneath the system clock are available for displaying the
icons. The first icon field is assigned to the MMC area. (Icon fields 2 and 3 are
assigned by the PLC, see Interface, Part 1).
Because the main memory capacity is not unlimited, some applications are mutu-
ally exclusive.
A "termination list" therefore exists for every application.
This list contains the applications that must be terminated to be able to start the
selected application.
Example:
The possible applications are defined by the following lines in the file BEDCONF:
'MASCHIN'
'PARAMET'
'DIAGNOS'
'ANWENDE'
'PLC_PR'
'DG_PLC'
where MACHINE is the 0th application, PARAMETER the 1st, SIMULATION the
14th.
In the WOP and SIMULATION applications the mutual exclusion is defined by the
following lines from the BEDCONF file:
'14'
'11'
'0'
'0'
'0'
'0'
'7'
'11'
'0'
'0'
'0'
'0'
For simulation this means that if they are running, the following applications must
be terminated before it can be started:
7
11
12
13
ManualsBase.com
'PROGRAM'
'ANWENDE'
'PROGSYS'
'PLC'
'MDD'
'IBN'
'12'
'13'
'0'
'0'
'0'
'0'
'12'
'13'
'0'
'0'
'0'
'0'
PROGSYS
(= WOP)
DG_PLC
(= S5 programming)
MDD
(= Machine data dialog)
IBN
(= Drive servo start-up)
4 MMC Area Diagnosis
4.4.3 BEDCONF configuration file
F
'DIENSTE'
\
'PLC_DG'
\
'SIMULAT'
//BAPPLDH-
NAM
'0'
\
'0'
\
'0'
//TermiWOP
'0'
\
'0'
\
'0'
//TermiSimu-
lation
4–35