Siemens SINUMERIK 840C Installation Instructions Manual page 484

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

12.93
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bits 6-7
Bit 8
Bits 9-14
Bit 15
Note:
Power on 611D alarms can be acknowledged only via a hardware reset.
1601
This machine data allows reset 611D alarms to be concealed or disabled. The alarm is active if
the appropriate bit = 0. All 611D alarms are activated as standard.
Bit 0
Bits 1-7
Bit 8
Bits 9-13
Bit 14
Bit 15
Note:
Reset 611D alarms can be acknowledged via a software reset.
1602
Input of maximum permissible motor temperature. The temperature is detected by appropriate
sensors and evaluated in the drive. A message is transferred to the SERVO when the warning
limit is reached.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Internal error cannot be concealed
Not assigned
Measuring circuit error, phase current R
Measuring circuit error, phase current S
Measuring circuit error, position measuring system motor
Measuring circuit error, position measuring system motor (absolute track optical
encoder)
Not assigned
Zero monitoring position (zero mark) measuring system motor
Not assigned
Temperature power section shutdown
Concealable reset 611D alarms
Default value
Lower input limit
0000
0000
Configuration error cannot be concealed
Not assigned
Speed controller at fixed stop
Not assigned
Shutdown motor overtemperature
Not assigned
Motor temperature warning limit
Default value
Lower input limit
120
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
Upper input limit
FFFF
Upper input limit
0
200
6FC5197- AA50
7.2.2 FDD MD (data description - SW 3)
Active
at once
Units
Hex
Active
at once
Units
°C
7–69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents