Siemens SINUMERIK 840C Installation Instructions Manual page 450

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

12.93
Description of user-programmable messages:
| n
The PLC status message is set when | n
Ramp-up complete (function no. 2)
The PLC status message is set when the actual speed value corresponds to the setpoint,
allowing for the tolerance band set in MD 27. This status message is not output when the
speed fluctuates as a result of load changes.
| M
The PLC status message is set when | M
referred to the currently active speed-dependent torque limit. If the PLC status message
n
act
< M
been reset.
| n
The PLC status message is set when | n
Motor overtemperature prewarning (function no. 5)
The PLC status message is set when the maximum motor temperature is reached (MD 63
for motor 1, MD 291 for motor 2). If the message does not disappear, then the drive
module is shut down with the "Motor overtemperature" alarm after the delay which can be
set in MD 65.
Heat sink overtemperature prewarning (function no. 6)
The PLC status message is set when the temperature switch of the main heat sink
responds. If the message does not disappear, then the drive module is shut down after
approximately 2 minutes with the "Heat sink overtemperature" alarm.
Variable relay function 1 (function no. 7)
MD 185
MD 186
MD 187
MD 188
MD 189
Variable relay function 2 (function no. 8)
MD 190
MD 191
MD 192
MD 193
MD 194
n
act
The PLC status message is set when severe speed fluctuations occur as a result of load
changes.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
| < n
(function no. 1)
act
min
| < M
(function no. 3)
d
dx
= n
is set when the speed setpoint is changed, then the PLC status message | M
set
cannot be reset for at least 800 ms after the PLC status message n
dx
| < n
(function no. 4)
act
x
Address for monitoring 1
Threshold for monitoring 1
ON-delay monitoring 1
Drop delay monitoring 1
Hysteresis monitoring 1
Address for monitoring 2
Threshold for monitoring 2
ON-delay monitoring 2
Drop delay monitoring 2
Hysteresis monitoring 2
= n
(function no. 20)
set
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
7.1.2 MSD MD (data description - SW 3)
| < n
. Settable in MD 21.
act
min
| > M
. The percentage setting in MD 47 is
d
dx
| < n
. Settable in MD 23.
act
x
6FC5197- AA50
|
d
= n
has
act
set
0000 ... FFFFH
0000 ... FFFFH
0 ... 10.00 ms
0 ... 10.00 ms
0000 ... FFFFH
0000 ... FFFFH
0000 ... FFFFH
0 ... 10.00 ms
0 ... 10.00 ms
0000 ... FFFFH
7–35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents