10.94
1.5
1.5.1
NC area
The checksum of the system program memory is generated whenever the control is switched
on (Power On routines) and during cyclic operation. The control flags discrepancies between
reference and actual checksum in different ways.
The NC CPU flashes continuously (red LED) and goes into the stop state.
MMC area:
If the tests are carried out without any interruptions, the following messages appear in the
MMC area on the screen:
386 Modular BIOS v3.05acf, MR0 1.45
Copyright (c)1984-90 Award Software Inc.
TESTING INTERRUPT CONTROLLER #1 . . . . . . . . . . . . . . . . . . . . . . .
TESTING INTERRUPT CONTROLLER #2 . . . . . . . . . . . . . . . . . . . . . . .
TESTING CMOS BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TESTING CMOS CHECKSUM
TESTING EXTENDED CHECKSUM
SIZING SYSTEM MEMORY . . . . . . . . . . . . . . . . . . . . . . . . . .
TESTING SYSTEM MEMORY
CHECKING UNEXPECTED INTERRUPTS AND STUCK NMI . . . . . . . . . .
TESTING PROTECTED MODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SIZING EXTENDED MEMORY . . . . . . . . . . . . . . . . . . . . . . . .
TESTING MEMORY IN PROTECTED MODE . . . . . . . . . . . . . .
TESTING PROCESSOR EXCEPTION INTERRUPTS . . . . . . . . . . . . . . .
BIOS SHADOW RAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VIDEO SHADOW RAM
Powering up
Hard-disk check (as from SW 4)
During booting from the MMC area, the consistency of the hard disk is checked. This check is
time-dependent and is performed once every week. In this context, it is important to note that
free disk space can be reduced due to lost clusters resulting from frequent switching on and
off the control. It is only by means of a hard-disk check that this disk space can once again be
made available. For this reason, a hard-disk check is also initiated if the remaining available
disk space drops to less than 1 MB.
The setting for the hard-disk check is possible only in the Service Mode and can be carried
out by the system service only.
_______
*
BIOS version
© Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on

Voltage and functional tests

Self-test and system start-up

(c)1991-92 SIEMENS AG ERLANGEN
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ManualsBase.com
*
. . . . . . . . . . . . . . . . . . . . . . . . . . .
6FC5197- AA50
1 Prerequisites and Visual Inspection
1.5.1 Self-test and system start-up
PASS
PASS
PASS
PASS
PASS
640K
FOUND
PASS
PASS
PASS
3072K
FOUND
3072K
PASS
PASS
ENABLED
ENABLED
1–9