Siemens SINUMERIK 840C Installation Instructions Manual page 535

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
1413
Default value
0
This machine data allows adaptation of the speed controller machine data to be controlled as a
function of speed.
Input 0:
Input 1:
Note:
The adaptation function is automatically activated by the Calculate controller data operation
for main spindle drives.
1414
Default value
0.0
Input of natural frequency for the "Speed control loop" reference model. The filter is
deactivated if a value of < 10 Hz is entered (proportional element with a gain of 1).
Note:
Machine data MD 1414, MD 1415 and MD 1416 must be set in each case to the same value
for interpolating axes.
7–120
More user manuals on
Selection adaptation speed controller
Lower input value
0
The adaptation function is not active. The settings in control machine data
MD 1407 and MD 1409 are applicable over the entire speed range. Control
machine data MD 1408 and MD 1410 are not taken into account.
The adaptation function is active. See machine data MD 1411 and MD 1412 for
description.
Natural frequency reference model speed
Lower input value
0.0
ManualsBase.com
Upper input value
1
Upper input value
8 000.0
©
Siemens AG 1992 All Rights Reserved
09.95
Active
at once
Units
Active
at once
Units
Hz
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents