c) The already altered characteristics of a data are to be changed again or
the characteristics of another data in the same display are to be changed.
If the data list of this display was already copied into the user branch
when the first change was made and if the data list was not changed
when the texts and input limits were changed again, these new changes to
the texts and input limits will not automatically be included.
In order to save time during display generation only one alteration to the
data list is automatically recognized (by the date in the file).
The changes made to the text or semantics list are accepted with the key
combination "@" and "!" (in the list display).
The message "106001 List display [name] is being generated ..." appears
and the display is generated again.
6. Please note:
The message "106001 List display [name] is being generated ..." may in some
cases be hidden by higher priority alarms, or be displayed for too short a time.
However, under Diagnosis/Service displays/Alarm log 1 it is possible to find
out whether the message has already been issued. It is thus possible in the
cases mentioned above to check whether an alteration has been included for
the display generation.

Configuring the parameter set switchover in the list display

Three parameter set groups are supported by SW 4 and higher:
1) Parameter set position control (G1)
2) Parameter set speed ratio
3) Parameter set drive
For each of these groups exactly one parameter set is always selected for dis-
play in the list displays. This selection is valid for all displays, i.e. when the dis-
play is changed the selection remains valid and also applies to displays subse-
quently selected.
All three parameter set groups each have 8 parameter sets.
If all the parameter sets of a data are to be displayed one above the other, the
usual procedure is followed:
The data numbers are displayed in a data list.
Example:
2040
15400
15440
15480
15520
15560
15600
15640
In the drive machine data list the parameter set number is displayed with a colon.
Example:
1500:1
1500:2
1500:3
1500:4
1500:5
1500:6
1500:7
1500:8