Functional Description; Parameterization, Control And Programming - Siemens SINUMERIK 840C Installation Instructions Manual

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

10.94
12.20.1
The term "Extended stop and retract" refers to the error reactions listed below:
Parameterization of error reaction by means of machine data and part program commands
Monitoring sources (error identification)
Shutdown of machine in order to prevent damage to tool or workpiece wherever possible
Separation of tool and workpiece through traversing motions (retractions) initiated in the
event of an error/fault
The 840C system and SW version 4 provides an extended functionality for the retraction
operation. The axes/spindles (drives, motors, encoders, etc.) and the control involved in the
controlled stop and retract process must all be operational: If one of these components fails,
the full scope of the system reaction described below may not be available.
"Extended stop and retract" comprises the following functions:
Monitoring sources (error detection)
DC link buffering (generator operation)
Stopping and
Retraction
Both the sources for error detection and the reactions in the form of stop and retraction can be
parameterized via machine data (NC and drive)
controlled via the PLC and/or
programmed by means of G commands.
Both sources and reactions can be
internal and/or
external.
12.20.2
The "Extended stop and retract" function comprises:
1. Parameterization of the operating characteristics via machine data:
© Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on

Functional description

Parameterization, control and programming

General machine data:
To enable the new operating characteristics for the stop process
To parameterize the times for extended stopping
Machine data specific to channel/mode group:
To assign the mixed I/O modules for the retraction operation in the form of:
-
Inputs (external sources) and
-
Outputs (external reactions).
Application of internal sources:
-
Mode group stop
-
EMERGENCY STOP
which must initiate a retraction operation.
Definition of internal reactions to be initiated in the case of a retraction operation:
-
Alarm and mode group stop
-
Retraction operation as open-loop control function and/or as
-
Autonomous drive function
Machine data specific to axis/spindle:
To assigned the mixed I/O modules for the retraction operation in the form of:
-
Outputs (external reactions)
ManualsBase.com
6FC5197- AA50
12 Functional Descriptions
12.20.1 Functional description
12–213

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents