7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
When DELTA is calculated, it must be taken into account that the torque setpoint limitation
m
may change in cyclic operation. This limitation acts on the maximum speed difference
set,limit
n
.
max
n
=
––––––––––––––––––––––– x –––––––––––––––––––
max
Since the speed setpoint is specified by the NC, there is an operating time between the 611D
speed controller and the NC which is taken into account in the DELTA calculation through
machine data "Op. time factor IPO/NREG cyc. f. RFG" (MD 1665).
DELTA = n
max
Caution:
This machine data is relevant only for Siemens-internal purposes and must not be altered.
1700
Default value
0000
This machine data is used to display the status of the binary inputs.
Value table:
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Bits 9-15
1701
Default value
0
This machine data is used to display the voltage level at the DC link in normal or set-up mode.
The DC-link voltage V
7–156
More user manuals on
m
set, limit
n-controller P-gain
x MD 1665 (operating time factor)
Status of binary inputs
Lower output limit
0000
Control unit enable (internal module function), including marking
according to MD 1003, bit 5
Pulse enable (terminal 663) (module-specific pulse suppression)
Pulse enable (terminal 63/48) of I/RF unit (central drive pulse
suppression)
Sum signal HW pulse enable:
Temp. monitor heat sink responded
Setup mode (terminal 112) of I/RF unit (set-up mode message)
Drive enable (terminal 64/63) of I/RF unit (Central drive enable setpoint
= 0)
Not assigned
Motor and power section temp. prewarning
Not assigned
Lower output limit
0
is measured continuously.
DClink
ManualsBase.com
IPO cycle
Speed controller cycle
Upper output limit
7FFF
– Stored hardware sum signal
– Axial pulse enable by PLC via
611D control word
DC link voltage
Upper output limit
32 767
©
Siemens AG 1992 All Rights Reserved
07.97
Active
at once
Units
Hex
0: off
1: on
0: off
1: on
Active
at once
Units
V
6FC5197- AA50