7 Drive Machine Data (SIMODRIVE Drive MD)
7.3.2 Drive MD (data description)
1150
Default value
400.0
Input of the proportional gain of the flux controller or automatic paramterization (initialization)
through the operator action Calculate controller data.
Note:
This data is relevant only for MSD drives.
1151
Default value
10.0
Input of the control variable integral-action time flux controller or automatic paramterization by
the operator action Calculate controller data.
1160
Default value
1 500.0
Above the set speed flux detection is active, below the set speed a flux model is used. The
parameter default is set for "Calculate controller data" and should not be changed.
Note:
This machine data only applies to main spindle drives.
1161
Default value
600
0 (as from SW 6)
By specifying a DC link fixed voltage > 0V DSP internal DC link measurement is deactived
here, i.e. MD 1701 (between loop voltage display) is inactive (display: "
The given voltage is included instead of the measurement in:
DC link adaptation
Flux acquisition (MSD)
The permissibility of an activation of the DC link measurement (MD 1161=0) is monitored in
accordance with hardware configuration 5 (error message 300765).
Caution:
It is not possible to activate emergency retractive functions with deactivated DC link
measurement (MD 1161 > 0) (error message 300764).
7–98
More user manuals on
P gain flux controller
Lower input limit
0.0
Integral-action time flux controller
Lower input limit
0.0
Speed for start of flux detection
Lower input limit
200.0
DC link fixed voltage
Lower input limit
0
ManualsBase.com
Upper input limit
100 000.0
Upper input limit
500.0
Upper input limit
50 000.0
Upper input limit
700
©
Siemens AG 1992 All Rights Reserved
07.97
Active
at once
Units
A/Vs
Active
at once
Units
ms
Active
at once
Units
rev/min
Active
at once
Units
V
*
").
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents