12.93
1106
When the power section order number (machine-readable product designation for Siemens
power sections) is input during initial start-up, it is converted to a code number as an MMC
function (the user need not enter a code number). The following power section data are
automatically transferred from an internal power section table through the input of the code
number:
Limit current transistor (MD 1107)
maximum thermal current of the power section (MD 1108)
Format of power section code number:
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
1107
Input of maximum permissible current of power section. This input makes allowance for the
rating of the transistors minus thermal reserves (approximately 20 %). The maximum current
must be set as a peak value independently of the pulse frequency. This machine data is
automatically parameterized for Siemens power sections by the machine data "Power section
code" (MB 1106).
Caution:
This data serves as the basis for normalizing the current actual value sensor and must not be
changed by the user after automatic presetting of its values.
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Default value
Lower input limit
0000
0000
Power section type
MSD
FDD
Not assigned
Default value
Lower input limit
200
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
Power section code
Upper input limit
00FF
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Limit current transistor
Upper input limit
1
500
6FC5197- AA50
7.2.2 FDD MD (data description - SW 3)
Active on
Power On
Units
Hex
Amperage
No power section specified
3 / 6 A
5 / 10 A
Not assigned
9 / 18 A
Not assigned
18 / 36 A
28 / 56 A
Not assigned
56 / 112 A
70 / 140 A
Not assigned
Active on
Power On
Units
A