2 General Reset and Standard Start-Up

2.6 Loading machine data (as from SW 3)

2.6
Note
Selection
Procedure
Initial start-up
Subsequent start-up
2-8
More user manuals on
Loading machine data (as from SW 3)
Loading the machine data function takes several seconds and is accompanied by
the flashing message "Wait".
The following softkeys must be pressed: Diagnosis, Startup, Machine data, File
functions:
Fig. 2.2
Step
1
Activate the standard
data window with the
2
Select STANDD_T or
STANDD_M
3
SK Load from disk
4
Select STANDARD
5
SK Load from disk
On initial start-up (state as supplied from Siemens), no files are available in the
"User data" window(see Fig.).
On subsequent start-up, user files from the "User data" window can be loaded
instead of the files STANDD_T, STANDD_M, STANDARD in the "Standard data"
window.
Make sure that no communication is taking place with the digital drive systems. If
the user file contains drive data (TEA3), you must acknowledge the drive-specific
ManualsBase.com
Operation
The window has a yellow border
key
NC-MD
PLC MD, cycl. MD
Siemens AG 2001 All Rights Reserved 6FC5197–jAA50
09.95
Comment
The MD in the NCK
area are cleared
and assigned stan-
dard values
dard values