Siemens SINUMERIK 840C Installation Instructions Manual page 510

Hide thumbs Also See for SINUMERIK 840C:
Table of Contents

Advertisement

07.97
1139
Input of stator leakage reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
* Active on "Power On" until SW < 6
1140
Input of rotor leakage reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
* Active on "Power On" until SW < 6
1141
Input of magnetizing reactance as specified on the motor data sheet (non-Siemens motor) or
automatic parameterization using machine data "Motor code number" (MD 1102).
Note:
This data is relevant only for MSD drives.
* Active on "Power On" until SW < 6
1142
Input of speed at which field weakening starts as specified on the motor data sheet (non-
Siemens motor) or automatic parameterization using machine data "Motor code number"
(MD 1102). In the field-weakening range, the magnetizing inductivity L
the saturated value at the speed at which field weakening begins to the unsaturated value at
the upper limit speed of the L
Note:
This data is relevant only for MSD drives.
* Active on "Power On" until SW < 6
©
Siemens AG 1992 All Rights Reserved
SINUMERIK 840C (IA)
More user manuals on
Default value
Lower input limit
0.0
Default value
Lower input limit
0.0
Default value
Lower input limit
0.0
Speed at start of field weakening
Default value
Lower input limit
0.0
characteristic (see diagram MD 1144).
h
ManualsBase.com
7 Drive Machine Data (SIMODRIVE Drive MD)
Stator leakage reactance
Upper input limit
0.0
100.0
Rotor leakage reactance
Upper input limit
0.0
100.0
Magnetizing reactance
Upper input limit
0.0
1 000.0
Upper input limit
0.0
50 000.0
6FC5197- AA50
7.3.2 Drive MD (data description)
Active
at once*
Units
Active
at once*
Units
Active
at once*
Units
Active
at once*
Units
rev/min
increases linearly from
h
7–95

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents