3.2

Mounting the motor

For mounting conditions, see Technical data - servo motors (Page 46).
3.2.1

Mounting orientation and dimensions

Mounting orientation
SIMOTICS S-1FL6 supports flange mounting only and three types of constructions, so it can
be installed in three orientations as shown in the following figure.
Note
When configuring the IM V3 type of construction, pay particular attention to the permissible
axial force (weight force of the drive elements) and the necessary degree of protection.
Motor dimensions
Shaft-height 45 mm, with incremental encoder (unit: mm)
Rated power
0.4 kW
0.75 kW
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Rated torque
1.27 Nm
2.39 Nm
k
k1
a
154.5
201
169.5
201.5
248
216.5
Mounting
3.2 Mounting the motor
b
b1
15
61.5
57