Parameters
10.2 Parameter list
Par. No.
Name
p1423
Speed setpoint filter 2
denominator natural fre-
quency
Description: Sets the denominator natural frequency for speed setpoint filter 2 (PT2, general filter).
Dependency: Refer to p1414, p1421
Note: This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general
filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
p1424
Speed setpoint filter 2
denominator damping
Description: Sets the denominator damping for speed setpoint filter 2 (PT2, general filter).
Dependency: Refer to p1414, p1421
Note: This parameter is only effective if the speed filter is parameterized as a PT2 low pass or as general
filter.
p1425
Speed setpoint filter 2
numerator natural fre-
quency
Description: Sets the numerator natural frequency for speed setpoint filter 2 (general filter).
Dependency: Refer to p1414, p1421
Note: This parameter is only effective if the speed filter is set as a general filter.
The filter is only effective if the natural frequency is less than half of the sampling frequency.
p1426
Speed setpoint filter 2
numerator damping
Description: Sets the numerator damping for speed setpoint filter 2 (general filter).
Dependency: Refer to p1414, p1421
Note: This parameter is only effective if the speed filter is set as a general filter.
p1441
Actual speed smoothing
time
Description: Sets the smoothing time constant (PT1) for the speed actual value.
Note: The speed actual value should be smoothed for increment encoders with a low pulse number.
After this parameter has been changed, we recommend that the speed controller is adapted and/or the speed
controller settings checked Kp (p29120) and Tn (p29121).
p1520 *
Torque limit upper
Description: Sets the fixed upper torque limit.
Danger: Negative values when setting the upper torque limit (p1520 < 0) can result in the motor accelerating
in an uncontrollable fashion.
Notice: The maximum value depends on the maximum torque of the connected motor.
p1521 *
Torque limit lower
Description: Sets the fixed lower torque limit.
Danger: Positive values when setting the lower torque limit (p1521 > 0) can result in the motor accelerating in
an uncontrollable fashion.
Notice: The maximum value depends on the maximum torque of the connected motor.
260
Min
Max
0.5
16000.0
0.001
10.000
0.5
16000.0
0.000
10.000
0.00
50.00
-1000000.00
20000000.0
0
-20000000.00
1000000.00 0.00
Factory
Unit
Data
Setting
type
1999.0
Hz
Float
0.700
-
Float
1999.0
Hz
Float
0.700
-
Float
0.00
ms
Float
0.00
Nm
Float
Nm
Float
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0