10.2

Parameter list

Editable parameters
The values of the parameters marked with an asterisk (*) may be changed after
commissioning. Make sure you back up the parameters first as required if you desire to
replace the motor. The default values of the parameters marked with two asterisks (**) are
motor dependent. They may have different default values when different motor connected.
Par. No.
Name
p1001
Fixed speed setpoint 1
Description: Sets a value for the fixed speed / velocity setpoint 1.
p1002
Fixed speed setpoint 2
Description: Sets a value for the fixed speed / velocity setpoint 2.
p1003
Fixed speed setpoint 3
Description: Sets a value for the fixed speed / velocity setpoint 3.
p1004
Fixed speed setpoint 4
Description: Sets a value for the fixed speed / velocity setpoint 4.
p1005
Fixed speed setpoint 5
Description: Sets a value for the fixed speed / velocity setpoint 5.
p1006
Fixed speed setpoint 6
Description: Sets a value for the fixed speed / velocity setpoint 6.
p1007
Fixed speed setpoint 7
Description: Sets a value for the fixed speed / velocity setpoint 7.
p1058
Jog 1 speed setpoint
Description: Sets the speed/velocity for jog 1. Jogging is level-triggered and allows the motor to be incremen-
tally moved.
Note: The parameter values displayed on the BOP are integers.
p1082 *
Description: Maximum
speed
Description: Sets the highest possible speed.
Notice: After the value has been modified, no further parameter modifications can be made.
Note: The parameter values displayed on the BOP are integers.
The parameter applies for both motor directions.
The parameter has a limiting effect and is the reference quantity for all ramp-up and ramp-down times (e.g.
down ramps, ramp-function generator and motor potentiometer).
The range of the parameter is different when connect with different motors.
p1083 *
Speed limit in positive
direction of rotation
Description: Sets the maximum speed for the positive direction.
Note: The parameter values displayed on the BOP are integers.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Min
Max
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 00.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
-210000.000
210000.000 0.000
0.00
210000.000 100.00
0.000
210000.000 1500.00
0.000
210000.000 210000.
Factory
Unit
Data
Setting
type
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
rpm
Float
0
rpm
Float
000
Parameters
10.2 Parameter list
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T
IM
T, U
255