Parameter
p29012[2]
p29012[3]
p29013
These four electronic gear ratios can be selected with the combination of the digital input
signals EGEAR1 and EGEAR2 (refer to Section "DIs (Page 70)"):
Note
After a gear ratio is switched to another one via digital inputs, you need to wait five seconds
and then perform SERVO ON.
Note
The range of electronic gear ratio is from 0.02 to 200.
The electronic gear ratio can be set at SERVO OFF state only. After the setting, you need to
reference the drive again.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Range
1 to 10000
1 to 10000
1 to 10000
EGEAR2 : EGEAR1
0 : 0
0 : 1
1 : 0
1 : 1
Factory setting
Unit
1
-
1
-
1
-
Electronic gear ratio
Electronic gear ratio 1
Electronic gear ratio 2
Electronic gear ratio 3
Electronic gear ratio 4
7.3 Pulse train input position control (PTI)
Description
The third numerator of electronic gear
The forth numerator of electronic gear
The denominator of electronic gear
Ratio value
p29012[0] : p29013
p29012[1] : p29013
p29012[2] : p29013
p29012[3] : p29013