Siemens SINAMICS V90 Operating Instructions Manual page 71

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

No.
Name
Type
10
TLIM1
Level
11
TLIM2
Level
12
CWE
Level
13
CCWE
Level
14
ZSCLAMP
Level
15
SPD1
Level
16
SPD2
Level
17
SPD3
Level
18
TSET
Level
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Description
Torque limit selection.
A combination of TLIM1 and TLIM2 can select four
torque limit sources (one external torque limit, three
internal torque limits).
TLIM2 : TLIM1
0 : 0: internal torque limit 1
0 : 1: external torque limit (analog input 2)
1 : 0: internal torque limit 2
1 : 1: internal torque limit 3
Enable clockwise rotations.
1: Enable clockwise rotation, ramp up
0: Disable clockwise rotation, ramp down
Enable counter-clockwise rotations.
1: Enable counter-clockwise rotation, ramp down
0: Disable counter-clockwise rotation, ramp up
Zero speed clamps.
1 = when the motor speed setpoint is an analog
signal and lower than the threshold level (p29075),
the motor is clamped.
0 = no action
Select speed mode: fixed speed setpoint.
A combination of the signals SPD1, SPD2 and SPD3
can select eight speed setpoint sources (one external
speed setpoint, seven fixed speed setpoints).
SPD3 : SPD2 : SPD1
0 : 0 : 0: external analog speed setpoint
0 : 0 : 1: fixed speed setpoint 1
0 : 1 : 0: fixed speed setpoint 2
0 : 1 : 1: fixed speed setpoint 3
1 : 0 : 0: fixed speed setpoint 4
1 : 0 : 1: fixed speed setpoint 5
1 : 1 : 0: fixed speed setpoint 6
1 : 1 : 1: fixed speed setpoint 7
Torque setpoint selection.
This signal can select two torque setpoint sources
(one external torque setpoint, one fixed torque set-
point).
0: external torque setpoint (analog input 2)
1: fixed torque setpoint
Connecting
4.3 Control/Status interface - X8
Control mode
PTI
IPos
S
X
X
X
X
X
X
X
X
X
X
X
T
X
X
X
71