Par. No.
Name
p2574
EPOS jerk limiting
Description: Sets the jerk limiting.
Dependency: Refer to p2572, p2573, p2575
Note: The jerk limiting is internally converted into a jerk time as follows:
Jerk time Tr = max(p2572, p2573) / p2574
p2580
EPOS software limit
switch minus
Description: Sets the software limit switch in the negative direction of travel.
Dependency: Refer to p2581, p2582
p2581
EPOS software limit
switch plus
Description: Sets the software limit switch in the positive direction of travel.
Dependency: Refer to p2580, p2582
p2582
EPOS software limit
switch activation
Description: Sets the signal source to activate the "software limit switch".
Dependency: Refer to p2580, p2581
Caution: Software limit switch effective:
- Axis is referenced.
Software limit switch ineffective:
- Modulo correction active.
- Search for reference is executed.
Notice: Target position for relative positioning outside software limit switch:
The traversing block is started and the axis comes to a standstill at the software limit switch. An appropriate
alarm is output and the traversing block is interrupted. Traversing blocks with valid position can be activated.
Target position for absolute positioning outside software limit switch:
In the "traversing blocks" mode, the traversing block is not started and an appropriate fault is output.
Axis outside the valid traversing range:
If the axis is already outside the valid traversing range, then an appropriate fault is output. The fault can be
acknowledged at standstill. Traversing blocks with valid position can be activated.
Note: The traversing range can also be limited using STOP cams.
p2583
EPOS backlash compen-
sation
Description: Sets the amount of play (backlash) for positive or negative play.
= 0: The backlash compensation is de-activated.
> 0: Positive backlash (normal case)
When the direction is reversed, the encoder actual value leads the actual value.
< 0: Negative backlash
When the direction is reversed, the actual value leads the encoder actual value.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Min
Max
1
100000000
-2147482648
214748264
7
-2147482648
214748264
7
-
-
-200000
200000
Factory
Unit
Data
Setting
type
10000
100
U32
0
LU/s
3
-
LU
I32
214748
2648
214748
LU
I32
2647
0
-
U32/Bina
ry
0
LU
I32
Parameters
10.2 Parameter list
Effective
Can be
changed
IM
T, U
IM
T, U
IM
T, U
IM
T
IM
T, U
265