9.9.5

PI/P switching using pulse deviation

The speed loop is switched from PI control to P control when the pulse deviation exceeds
the preset value (p29144).
Parameter settings
Parameter
Value range
p29140
0 to 5
p29144
0 to 2147483647
p29120[0]
0 to 999999
p29121[0]
0 to 100000
Note
Speed setpoint
For detailed information about speed setpoint, refer to "Configuring speed setpoint
(Page 174)".
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Setting value
Unit
5
-
30000 (default)
-
0.3 (default)
Nms/rad
15 (default)
ms
Description
Switches PI control to P control using pulse deviation
Pulse deviation threshold for automatically triggering PI
to P switching
Speed loop gain 1
Speed loop integral time 1
Tuning
9.9 PI/P switching
251