Adjusting cable orientations from the motor side
From the motor side, you can adjust the orientation of the power cable, encoder cable, and
brake cable to facilitate cable connection.
Note
Rotating the connectors
All the three motor-side connectors can be rotated only within 360°.
4.2

Main circuit wirings

4.2.1

Line supply - L1, L2, L3

400 V variant
Maximum conductor cross-section:
FSAA and FSA: 1.5 mm
FSB and FSC: 2.5 mm
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Signal
L1
L2
L3
(M2.5 screws, 4.43 lb.in/0.5 Nm)
2
(M4 screws, 19.91 lb.in/2.25 Nm)
2
4.2 Main circuit wirings
Description
Line phase L1
Line phase L2
Line phase L3
Connecting