Siemens SINAMICS V90 Operating Instructions Manual page 38

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

General information
2.5 Accessories
resistor to the external braking resistor. You can select a standard braking resistor according
to the table below:
Frame size
FSAA
FSA
FSB
FSC
Filter
Siemens recommends you to use a line filter to protect the system from high frequency noise.
The line filter restricts the conductive interference emitted from the SINAMICS V90 to the
permissible values. The SINAMICS V90 drives with these external line filters have been
tested in accordance with the emission requirements of the Category C2 environment. The
conductive emissions and radiated emissions are in compliance with the Class A
requirements of the EN 55011 standard.
The table below lists all filters recommended by Siemens:
Frame size Rated current (A)
FSAA
FSA
FSB
FSC
Outline dimensions (mm)
38
Resistance (Ω)
Max. power (kW)
533
1.2
160
4
70
9.1
27
23.7
Degree of protection
5
IP20
5
IP20
12
IP20
20
IP20
Rated power (W)
30
100
229
1185
Order number
6SL3203-0BE15-0VA0
6SL3203-0BE15-0VA0
6SL3203-0BE21-2VA0
6SL3203-0BE22-0VA0
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Max. energy (kJ)
2.4
8
18.3
189.6