Parameters
10.2 Parameter list
Par. No.
Name
Notice: Only for internal Siemens troubleshooting.
Note: The value of -200 indicates that there is no measuring signal.
r0037[0]: Maximum value of the inverter temperatures (r0037[5...10]).
•
r0037[1]: Maximum value of the depletion layer temperatures (r0037[13...18]).
•
r0037[2]: Maximum value of the rectifier temperatures (r0037[11...12]).
•
The maximum value is the temperature of the hottest inverter, depletion layer, or rectifier.
r0079[0...1]
Torque setpoint total
Description: Displays and connector output for the torque setpoint at the output of the speed controller
(before clock cycle interpolation).
Index:
[0]: Unsmoothed
•
[1]: Smoothed
•
r0296
DC link voltage undervoltage threshold
Description: Threshold to detect a DC link undervoltage.
If the DC link voltage falls below this threshold, the drive unit is tripped due to a DC link undervoltage
condition.
Note: The value depends on the device type and the selected device rated voltage.
r0297
DC link voltage overvoltage threshold
Description: If the DC link voltage exceeds the threshold specified here, the drive unit is tripped due to
DC link overvoltage.
Dependency: Refer to F30002.
r0311
Rated motor speed
Description: Displays the rated motor speed (rating plate).
r0333
Rated motor torque
Description: Displays the rated motor torque.
IEC drive: unit Nm
NEMA drive: unit lbf ft
r0482[0...2]
Encoder actual position value Gn_XIST1
Description: Displays the encoder actual position value Gn_XIST1.
Index:
[0]: Encoder 1
•
[1]: Encoder 2
•
[2]: Reserved
•
286
Unit
Nm
V
V
rpm
Nm
-
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Data type
Float
U16
U16
Float
Float
U32