Step
8
Select a pulse input channel by setting parameter
p29014.
9
Set the electronic gear ratio.
10
Set the torque limitation and speed limitation.
11
Configure necessary digital input signals by setting the
following parameters:
p29301[0]: DI1
p29302[0]: DI2
p29303[0]: DI3
p29304[0]: DI4
p29305[0]: DI5
p29306[0]: DI6
p29307[0]: DI7
p29308[0]: DI8
12
Check the encoder type.
If it is an absolute encoder, adjust the absolute encod-
er with the BOP menu function "ABS".
13
Set the pulse train encoder output.
14
Save parameters with the BOP.
15
Switch on the 3-phase 380 VAC power supply.
16
Clear faults and alarms.
17
Trigger SON to the high level, input the setpoint pulse
train from the command device, and then the servo
motor starts running.
18
The system commissioning in pulse train input position
control mode ends.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Description
5.2 Commissioning in pulse train position control mode (PTI)
p29014=0: high-speed 5 V differential pulse train input
(RS485)
p29014=1: 24 V single end pulse train input
24 V single end pulse train input is the factory setting.
Refer to "Selecting a setpoint pulse train input channel
(Page 143)".
You can use one of the following three methods to set the
electronic gear ratio:
Set the electronic gear ratio with parameters p29012
and p29013.
p29012: numerator of the electronic gear. Four
numerators in total (p29012[0] to p29012[3]) are
available.
p29013: denominator of the electronic gear.
Set the setpoint pluses per revolution.
p29011: number of setpoint pulses per revolution.
Calculate the electronic gear ratio by selecting me-
chanical structure.
For more information, see SINAMICS V90 V-
ASSISTANT Online Help.
Refer to "Electronic gear ratio (Page 145)".
Refer to "Torque limit (Page 151)" and "Speed limit
(Page 150)".
The factory settings are:
p29301[0]: 1 (SON)
p29302[0]: 2 (RESET)
p29303[0]: 3 (CWL)
p29304[0]: 4 (CCWL)
p29305[0]: 5 (G-CHANGE)
p29306[0]: 6 (P-TRG)
p29307[0]: 7 (CLR)
p99308[0]: 10 (TLIM1)
Refer to "Digital inputs/outputs (DIs/DOs) (Page 69)".
Refer to "Adjusting an absolute encoder (Page 134)".
Refer to "PTO function (Page 155)".
Refer to "Diagnostics (Page 291)".
Use a low pulse frequency at first to check the direction
and speed of rotation.
You can check the system performance. If it is not satis-
fied, you can adjust it. Refer to "Tuning (Page 223)".