Par. No.
Name
p29140
PI to P: Mode Selection
Description: Selects a condition for the switch from PI control to P control under the speed loop.
0: Disabled
1: Torque is higher than a parameterizable setting value.
2: Using the digital input signal (G-CHANGE).
3: Speed is higher than a parameterizable setting value.
4: Acceleration is higher than a parameterizable setting value.
5: Pulse deviation is higher than a parameterizable setting value.
Note: Only when the auto tuning function (p29021=0) and gain switching function are both disabled can the
PI/P switching function be used.
p29141
PI to P Switching Condi-
tion: Torque
Description: Triggers torque threshold for PI/P switching. If the PI/P switching function is enabled and this
condition is selected:
Switch from the PI control to the P control when the actual torque is larger than the threshold.
Switch from the P control to the PI control when the actual torque is smaller than the threshold.
p29142
PI to P Switching Condi-
tion: Speed
Description: Triggers speed threshold for PI/P switching. If the PI/P switching function is enabled and this
condition is selected:
Switch from the PI control to the P control when the actual speed is larger than the threshold.
Switch from the P control to the PI control when the actual speed is smaller than the threshold.
p29143
PI to P Switching Condi-
tion: Acceleration
Description: Triggers acceleration threshold for PI/P switching. If the PI/P switching function is enabled and
this condition is selected:
Switch from the PI control to the P control when the actual acceleration is larger than the threshold.
Switch from the P control to the PI control when the actual acceleration is smaller than the threshold.
p29144
PI to P Switching Condi-
tion: Pulse Deviation
Description: Triggers pulse deviation threshold for PI/P switching. If the PI/P switching function is enabled and
this condition is selected:
Switch from the PI control to the P control when the actual pulse deviation is larger than the threshold.
Switch from the P control to the PI control when the actual pulse deviation is smaller than the threshold.
p29240
Select Referencing Mode
Description: Selects referencing mode.
0: Referencing with external signal REF
1: Referencing with external reference cam (signal REF)
2: Referencing with zero mark only
3: Referencing with external reference cam (CCWL) and zero mark
4: Referencing with external reference cam (CWL) and zero mark
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Min
Max
0
5
0
300
0
210000
0
30000
0
214748364
7
0
4
Factory
Unit
Data
Setting
type
0
-
U16
200
%
Float
2000
rpm
Float
20
rev/
Float
30000
LU
U32
1
-
I16
Parameters
10.2 Parameter list
Effective
Can be
changed
IM
T
IM
T
IM
T
IM
T
IM
T
IM
T
277