2.7 Technical data
Power derating
For deviating conditions (surrounding temperature > 40 °C or installation altitude > 1000 m
above sea level) the permissible torque/power must be determined from the following table.
Surrounding temperatures and installation altitudes are rounded off to 5 °C and 500 m
respectively.
Power derating as a function of the installation altitude and ambient temperature
Installation altitude above
sea level (m)
1000
1500
2000
2500
3000
3500
4000
48
Surrounding temperature in °C
< 30
30 to 40
1.07
1.00
1.04
0.97
1.00
0.94
0.96
0.90
0.92
0.86
0.88
0.82
0.82
0.77
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
45
50
0.96
0.92
0.93
0.89
0.90
0.86
0.86
0.83
0.82
0.79
0.79
0.75
0.74
0.71
SINAMICS V90, SIMOTICS S-1FL6
55
0.87
0.84
0.82
0.78
0.75
0.71
0.67

Hide quick links: