System Features; Sto Functional Safety Data; Certification; Safety Instructions - Siemens SINAMICS V90 Operating Instructions Manual

Hide thumbs Also See for SINAMICS V90:
Table of Contents

Advertisement

8.3

System features

8.3.1

STO functional safety data

The STO functional safety data of SINAMICS V90 is as follows:
Applied standards
Type
Safety Integrity Level (SIL)
Hardware Fault Tolerance (HFT)
Probability of Failure per Hour (PFH)
8.3.2

Certification

The safety function of the SINAMICS V90 drive system meets the following requirements:
● Category 3 according to ISO 13849-1:2006
● Performance Level (PL) d to ISO 13849-1:2006
● Safety integrity level 2 (SIL 2) to IEC 61508
In addition, the safety function of SINAMICS V90 has been certified by independent institutes.
An up-to-date list of certified components is available on request from your local Siemens
office.
8.3.3

Safety instructions

Note
Additional safety information and residual risks not specified in this section are included in
the chapter "Safety instructions (Page 11)".
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Safety Integrated function
IEC 61508, IEC 62061, ISO 13849-1
A
2
1
5 × 10
per hour
-8
8.3 System features
215

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simotics s-1fl6

Table of Contents