Fixed position setpoint
Fixed position setpoint 5
Fixed position setpoint 6
Fixed position setpoint 7
Fixed position setpoint 8
Parameter settings
Parameter
Range
p2617[0]...[7]
-2147482648 to
2147482647
p2618[0]...[7]
1 to 40000000
p2572
1 to 2000000
p2573
1 to 2000000
Note
When the motor is working in the IPos control mode, you need to check that whether the
values of the parameters p2542, p2544, p2546, p2547 and p2573 are your desired values.
The values are set automatically by the drive based on the encoder resolution.
SINAMICS V90, SIMOTICS S-1FL6
Operating Instructions, 07/2015, 6SL3298-0AV60-0BP0
Corresponding parameters
Parameter
Description
p2617[4]
Fixed position setpoint 5 (P_pos5)
p2618[4]
Speed of fixed position setpoint 5 (P_pos_spd5)
p2572
IPos maximum acceleration
p2573
IPos maximum deceleration
p2617[5]
Fixed position setpoint 6 (P_pos6)
p2618[5]
Speed of fixed position setpoint 6 (P_pos_spd6)
p2572
IPos maximum acceleration
p2573
IPos maximum deceleration
p2617[6]
Fixed position setpoint 7 (P_pos7)
p2618[6]
Speed of fixed position setpoint 7 (P_pos_spd7)
p2572
IPos maximum acceleration
p2573
IPos maximum deceleration
p2617[7]
Fixed position setpoint 8 (P_pos8)
p2618[7]
Speed of fixed position setpoint 8 (P_pos_spd8)
p2572
IPos maximum acceleration
p2573
IPos maximum deceleration
Factory setting
0
600
Motor dependent
Motor dependent
Unit
LU
Fixed position setpoint 1 to 8
1000
Speed of fixed position setpoint 1 to 8
LU/min
1000
IPos maximum acceleration
LU/s²
1000
IPos maximum deceleration
LU/s²
Control functions
7.4 Internal position control (IPos)
Description