Modbus - TRENDnet TI-PG1284i User Manual

12-port hardened industrial gigabit poe+ layer 2+ managed din-rail switch
Hide thumbs Also See for TI-PG1284i:
Table of Contents

Advertisement

TRENDnet User's Guide
Apply
Click Apply to save your changes to the Switch.
Refresh
Click Refresh to begin configuring this screen afresh.
Loop Guard Status
Port
This field displays a port number.
State
This field displays if the loop guard feature is enabled.
Status
This field displays if the port is blocked.
Loop Recovery
This field displays if the loop recovery feature is enabled.
Recovery
This field displays the recovery time for the loop recovery feature.
Time (min)

Modbus

MODBUS TCP supports different types of data format for reading. The primary four types
of them are:
Data Access Type
Bit access
Physical Discrete
Inputs
Internal Bits or
Physical
Coils
Word
Physical Input
access
Registers
(16-bit
Physical Output
access)
Registers
© Copyright 2016 TRENDnet. All Rights Reserved.
Function
Function Name
Note
Code
2
Read Discrete Inputs
Not support
now
1
Read Coils
Not support
now
4
Read Input
Registers
3
Read Holding
Not support
Registers
now
MODBUS Data Map and Information Interpretation of IE Switches
MODBUS base address of switches is 1001(decimal) for Function Code 4.
Address
Data
Interpretation
Offset
Type
System Information
0x0000
1 word
HEX
0x0001
16 words
ASCII
0x0020
16 words
ASCII
TI-PG1284i
Description
Vendor ID = 0x0b04
Vendor Name = "ABCDEFG Corp."
Word 0 Hi byte = 'A'
Word 0 Lo byte = 'B'
Word 1 Hi byte = 'C'
Word 1 Lo byte = 'D'
Word 2 Hi byte = 'E'
Word 2 Lo byte = 'F'
Word 3 Hi byte = 'G'
Word 3 Lo byte = ' '
Word 4 Hi byte = 'C'
Word 4 Lo byte = 'o'
Word 5 Hi byte = 'r'
Word 5 Lo byte = 'p'
Word 6 Hi byte = '.'
Word 6 Lo byte = '\0'
Product Name = "SWITCH"
Word 0 Hi byte = 'S'
Word 0 Lo byte = 'W'
Word 1 Hi byte = 'I'
Word 1 Lo byte = 'T'
96

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents