TRENDnet User's Guide
6-pin Removable Terminal Block
Input/Ouput
Function
PWR Input
Connects primary power source (ex. external power supply) to power the
device. Device will obtain power from this input first priority if available.
(+) & (-)
Please make sure to power supplies are turned off before wiring in.
Use a flat-head screw driver to loosen (counter-clockwise) or tighten
(clockwise) the wiring from the external power supply.
Please ensure that the external power supply is supplying within the
range of 48VDC ~ 57VDC @ 240W or above. 260W for max. PoE+ power.
Please note power supply is sold separately (model: TI-24048)
Device supports overload current protection and reverse polarity
protection.
RPS Input
Connects redundant power source (ex. external power supply) to power
the device. Device will obtain power from this input secondary priority if
(+) & (-)
primary power input is not available or has failed.
Please make sure to power supplies are turned off before wiring in.
Use a flat-head screw driver to loosen (counter-clockwise) or tighten
(clockwise) the wiring from the external power supply.
Please ensure that the external power supply is supplying within the
range of 48VDC ~ 57VDC @ 240W or above. 260W for max. PoE+ power.
Please note power supply is sold separately (model: TI-24048)
Device supports overload current protection and reverse polarity
protection.
ALM Output
Connects external alarm and sends output signal if fault is detected
based on DIP switch settings.
Supports an output with current carrying capacity of 1A @ 24V DC.
Note: Turn off the power before connecting modules or wires.
Calculate the maximum possible current in each power wire and common wire. Observe
all electrical codes dictating the maximum current allowable for each wire size. If current
go above the maximum ratings, the wiring could overheat, causing serious damage to
your equipment.
© Copyright 2016 TRENDnet. All Rights Reserved.
ALM DIP Switches
DIP No Name
State
Status
1
PWR
ON
Primary power input source alarm trigger enabled.
OFF
Primary power input source alarm trigger disabled.
2
RPS
ON
Redundant power input source alarm trigger enabled.
OFF
Redundant power input source alarm trigger disabled.
3
P1
ON
Ethernet port 1 link alarm trigger enabled.
OFF
Ethernet port 1 link alarm trigger disabled.
4
P2
ON
Ethernet port 2 link alarm trigger enabled.
OFF
Ethernet port 2 link alarm trigger disabled.
5
P3
ON
Ethernet port 3 link alarm trigger enabled.
OFF
Ethernet port 3 link alarm trigger disabled.
6
P4
ON
Ethernet port 4 link alarm trigger enabled.
OFF
Ethernet port 4 link alarm trigger disabled.
7
P5
ON
Ethernet port 5 link alarm trigger enabled.
OFF
Ethernet port 5 link alarm trigger disabled.
8
P6
ON
Ethernet port 6 link alarm trigger enabled.
OFF
Ethernet port 6 link alarm trigger disabled.
9
P7
ON
Ethernet port 7 link alarm trigger enabled.
OFF
Ethernet port 7 link alarm trigger disabled.
10
P8
ON
Ethernet port 8 link alarm trigger enabled.
OFF
Ethernet port 8 link alarm trigger disabled.
11
P9
ON
SFP slot 9 link alarm trigger enabled.
OFF
SFP slot 9 link alarm trigger disabled.
12
P10
ON
SFP slot 10 link alarm trigger enabled.
OFF
SFP slot 10 link alarm trigger disabled.
13
P11
ON
SFP slot 11 link alarm trigger enabled.
OFF
SFP slot 11 link alarm trigger disabled.
14
P12
ON
SFP slot 12 link alarm trigger enabled.
OFF
SFP slot 12 link alarm trigger disabled.