Reading Parameters

RGB LED Features

RGB Good Read Raising/Falling Time
This parameter specifies the time it will take for the RGB good read to change
the status from an Off state to Brightness state, or back.
The delay can be set within a range of zero (0) to 160000 milliseconds (16 sec-
onds) in 100ms increments. A setting of zero specifies no delay.
To set the time:
1. Determine the desired setting in milliseconds.
2. Divide the desired setting by 100 (setting is in 100ms increments). Pad the
result with leading zeroes to yield two digits. For example: 0 = 00, 5 = 05,
20 = 20, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT RGB GOOD READ RAISING TIME on
RBG GOOD READ FALLING TIME on
5. Scan the appropriate two digits from the keypad in
represent the duration which was determined in the steps above.
NOTE
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit.
This completes the procedure. See the following table for examples of how to
set this feature.
Table 13. RGB Good Read Raising/Falling Time Examples
STEP
ACTION
1
Desired Setting
2
Divide by 100
3
Scan ENTER/EXIT PROGRAMMING MODE
4
Scan SELECT RGB GOOD READ RAISING/FALLING TIME
Scan Two Characters From
5
Appendix D, Keypad
6
Scan ENTER/EXIT PROGRAMMING MODE
Product Reference Guide
If you make a mistake before the last character, scan the CANCEL bar code
to abort and not save the entry string. You can then start again at the
beginning.
EXAMPLES
100ms
01
'0' and '1'
page
98.
Appendix D,
200ms
1000ms (1 sec.)
02
10
'0' and '2'
'1' and '0'
Reading Parameters
page 96
or
Keypad, that
5000ms (5 secs.)
50
'5' and '0'