1D Symbologies

MSI Set Length 2

This feature specifies one of the bar code lengths for
page
179
Mode, or the second fixed length if in
Length includes the bar code's check, data, and full-ASCII shift characters. The
length does not include start/stop characters.
The length can be set from 1 to 50 characters. A setting of 0 specifies to ignore
this length (only one fixed length). See
detailed programming instructions.
$CMSL2
Select MSI Length 2 Setting
Make a mistake? Scan the CANCEL bar code to abort and
not save the entry string. You can then start again at the
beginning.
Product Reference Guide
179. Length 2 is the maximum label length if in
50 = Length 2 is 50 Characters
DEFAULT
Enter/Exit Programming Mode
MSI Length Control on
Variable Length on page
Fixed Length on page 179
"Set Length 2"
on page 250 for more
To configure this feature, scan the ENTER/EXIT bar code
above, then the bar code at left followed by digits from
the Alphanumeric characters in
pad
representing your desired character(s). End by
scanning the ENTER/EXIT bar code again.