D103412X012
RESOURCE BLOCK
CONFIGURE/SETUP
Top Level
 Configure/Setup
 Device Diagnostics
 Device Variables
Version
 Device Revision
 Firmware Revision
 Standby Firmware Revision
 Hardware Rev
 ITK Version
RESOURCE BLOCK
DEVICE DIAGNOSTICS
Top Level
 Configure/Setup
 Device Diagnostics
 Device Variables
RESOURCE BLOCK
DEVICE VARIABLES
Top Level
 Configure/Setup
 Device Diagnostics
 Device Variables
Options
 Diagnostics Options
 Function Block Options
 Miscellaneous Options
 Features Available
Features Available
 Reports
 Fault State
 Soft W Lock
 Multi‐bit Alarm (Bit‐Alarm) Support
Configure/Setup
 Resource Block Mode
 Write Lock
 Comm Timeout
 Options
 Alarm Handling
 Identification
 Version
Identification
 Device ID
 Electronics Serial Number
 Factory Serial Number
 Field Serial Number
 Tag Description
 Strategy
 Manufacturer
 Device Type
 Diagnostics Options
Device Diagnostics
 Resource Block Error
 Device State
 Write Lock
 Block Alarm
 Maintenance
Maintenance
 Restart Actions
 Fault State
 Set Fault State
 Clear Fault State
Instrument
 Identification
 Version
Device Variables
 Instrument
 Options
 DD Information
Miscellaneous Options
 Firmware Download
 Travel Control Capable
 Pressure Control Capable
 Pressure Fallback Capable
Write Lock
 Write Lock
 Write Priority
Comm Timeout
 Shed Remote Cascade
 Shed Remote Out
Options
 Diagnostics Options
 Function Block Options
 Miscellaneous Options
 Features Available
 Features Selected
Alarm Handling
 Alert Key
 Confirm Time
 Limit Notify
 Maximum Notify
 Block Alm Disabled
 Block Alarm Auto Acknowledge
 Disc Alm Disabled
 Discrete Alarm Auto Acknowledge
Function
Block Options
 AO
 DO
 AI
 DI
 PID
 IS
 OS
 MAI
Field Communicator Menu Structure
Function
Block Options
 AO
 DO
 AI
 DI
 PID
 IS
 OS
 MAI
Miscellaneous Options
 Firmware Download
 Travel Control Capable
 Pressure Control Capable
 Pressure Fallback Capable
Features Available
 Reports
 Fault State
 Soft W Lock
 Multi‐bit Alarm (Bit‐Alarm) Support
Features Selected
 Reports
 Fault State
 Soft W Lock
 Multi‐bit Alarm (Bit‐Alarm) Support
Resource Block Error
 Other
 Block Configuration Error
 Simulate Active
 Device Needs Maintenance Soon
 Memory Failure
 Lost Static Data
 Lost NV Data
 Device Needs Maintenance Now
 Power Up
 Out of Service
Write Lock
 Write Alarm Alarm State
 Write Lock
Block Alarm
 Block Alarm Alarm State
 Block Alarm Unacknowledged
Identification
 Device ID
 Electronics Serial Number
 Factory Serial Number
 Field Serial Number
 Tag Description
 Strategy
 Manufacturer
 Device Type
Version
 Device Revision
 Firmware Revision
 Standby Firmware Revision
 Hardware Rev
 ITK Version