Replacing The Module Base - Fisher FIELDVUE DVC6200f Instruction Manual

Digital valve controller for foundation fieldbus
Table of Contents

Advertisement

Maintenance and Troubleshooting
July 2013
Figure 7‐1. Printed Wiring Board Cable Connections
TERMINAL
BOX
W9924‐1

Replacing the Module Base

Refer to figure 8‐2 or 8‐4 for key number locations. Refer to figure 7‐2 for a view of the back of the PWB assembly
sub‐module.
Figure 7‐2. Back View of PWB Assembly Sub‐Module
TERMINAL BOX
CONNECTOR
PINS REMOVED FOR
GE39341
CONNECTOR KEYING
Note
To avoid affecting performance of the instrument, inspect the guide surface on the module and the corresponding seating area in
the housing before installing the module base assembly. These surfaces must be free of dust, dirt, scratches, and contamination.
Ensure the module base seal is in good condition. Do not reuse a damaged or worn seal.
236
MODULE BASE ASSEMBLY
HOUSING
CABLE
TO TERMINAL BOX
S
S
TRAVEL SENSOR CONNECTOR
Instruction Manual
PRINTED WIRING
BOARD
ASSEMBLY
CABLE TO TRAVEL SENSOR
D103412X012

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents