Table 4‐14. Transducer Block Parameter Definitions (Continued)
Label
PARAMETER_NAME
PERF_DIAG
PD Run
PD_COMMAND
PD Status
PD_STATUS
PD Configuration
PD_CONFIG
PD Extra
PD_EXTRA
Temperature Units
TEMPERATURE_UNITS
Pressure Units
PRESSURE_UNITS
Travel Units
TVL_UNITS
Length Units
LENGTH_UNITS
Area Units
AREA_UNITS
Spring Rate Units
SPRING_RATE_UNITS
MAI_CHANNEL_MAP
MAI Channel 1
MAI_CHANNEL_1
MAI Channel 2
MAI_CHANNEL_2
MAI Channel 3
MAI_CHANNEL_3
MAI Channel 4
MAI_CHANNEL_4
MAI Channel 5
MAI_CHANNEL_5
MAI Channel 6
MAI_CHANNEL_6
MAI Channel 7
MAI_CHANNEL_7
MAI Channel 8
MAI_CHANNEL_8
Output Block Selection
OUTBLOCK_SEL
PlantWeb Alerts Set PV Status
PWA_SET_STATUS
Index
RO /
Mode
Number
RW
88
1=PD On
AUTO
88.1
RW
MAN
2=PD Off
1=Not Running
88.2
RO
ALL
2=Running
88.3
RW
ALL
0
88.4
RW
ALL
C=1001
89
RW
ALL
F=1002
kPa=1133
bar=1137
psig=1143
90
RW
ALL
inHg=1155
inH2O=1146
Kg/cm
cm=1012
mm=1013
91
RW
ALL
in=1019
deg=1005
cm=1012
92
RW
ALL
mm=1013
in=1019
2
cm
=1025
2
93
RW
ALL
mm
=1027
2
in
=1030
N/m=1165
94
RW
ALL
lb/in=1596
95
MAN,
95.1
RW
1 through 13
OOS
MAN,
95.2
RW
1 through 13
OOS
MAN,
95.3
RW
1 through 13
OOS
MAN,
95.4
RW
1 through 13
OOS
MAN,
95.5
RW
1 through 13
OOS
MAN,
95.6
RW
1 through 13
OOS
MAN,
95.7
RW
1 through 13
OOS
MAN,
95.8
RW
1 through 13
OOS
MAN,
1: AO Block
96
RW
OOS
2: DO Block
MAN,
1: No
97
RW
OOS
2: Yes
Range
Initial Value
1=PD On
0
C
kPa
2
=1145
mm
mm
2
cm
N/m
1
2
3
4
5
6
7
8
1: AO Block
1: No
-Continued-
Detailed Setup—Transducer Block
Protect
Description
Category
Data Type: Enum
NONE
Controls whether PD will run or not.
Data Type: Enum
NONE
Status of performance diagnostics.
Data Type: Bit String
NONE
Bit string for configuring PD setup
and options.
Data Type: Uint32
Extra 32 bit integer for sending
NONE
values to PD.
SETUP
Data Type: Enum (Uint8)
SETUP
Data Type: Enum (Uint8)
Data Type: Enum (Uint8)
Travel units for spec sheet
SETUP
ACTUAL_TRAVEL and RATEDTRAVEL
only.
Data Type: Enum (Uint8)
SETUP
Not used for spec sheet
ACTUAL_TRAVEL OR RATEDTRAVEL
SETUP
Data Type: Enum (Uint8)
SETUP
Data Type: Enum (Uint8)
Data Type:Uint16 This defines
which transducer block channels will
be sent to each of the 8 MAI
SETUP
channels. No scaling or other
conversion will be done. Values will
be sent in the currently defined
SETUP
units. If set to 0, then no output to
MAI (status will be set to BAD).
SETUP
1=FINAL_VALUE
2=TRAVEL_TARGET
SETUP
3=FINAL_POSITION_VALUE
4=TRAVEL
5=SUPPLY_PRESS
SETUP
6=ACT_PRESS_A
7=ACT_PRESS_B
SETUP
8=ACT_PRESS_DIFF
9=DRIVE_SIGNAL
10=TRAVEL_DEVIATION
SETUP
11=TEMPERATURE
12=CYCLE_COUNT
SETUP
13=TRAVEL_ACCUM
Data Type: Enum (Uint8)
Controls which output block (AO or
SETUP
DO) the transducer block will
respond to.
Data Type: Enum (Uint8)
Controls whether the status of the
PV fed back to the output block from
SETUP
the transducer block will be affected
by an active PlantWeb alert.
July 2013
109