Field Communicator Menu Structure
July 2013
TRANSDUCER BLOCK
DETAILED SETUP
Top Level
Configure/Setup
Device Diagnostics
Device Variables
Configure/Setup
Basic Setup
Detailed Setup
Detailed Setup
Calibration
Transducer Block Mode
Protection
Response Control
Alerts
Instrument
Valve and Actuator
MAI Channel Map
Alert Handling
Alert Handling
PlantWeb Alert Simulate
Simulate Active Alerts
PlantWeb Alert Handling
PlantWeb Alert Handling
PlantWeb Alerts Set PV Status
Block Error Reporting
268
Response Control
Travel Tuning
Pressure Tuning
Travel Press Control
Input Characterization
Custom Characterization Table
Outblock Selection
MAI Channel Map
:MAI Channel 1
:MAI Channel 2
:MAI Channel 3
:MAI Channel 4
:MAI Channel 5
:MAI Channel 6
:MAI Channel 7
:MAI Channel 8
Simulate Active Alarms
Failed Active
Maint Active
Advise Active
Reference
:Trim Style 1
:Trim Style 2
:Stroke Time Open
:Stroke Time Close
Travel Tuning
:Travel Tuning Set
Travel Proportional Gain
Travel Velocity Gain
:Travel MLFB Gain
:Travel Integral Enable
:Travel Integral Gain
:Travel Integral Dead Zone
:Travel Integral Limit Hi
:Travel Integral Limit Lo
Performance Tuner
Stabilize / Optimize
Travel Press Control
:Travel/Pressure State
:Travel/Pressure Select
Travel Deviation Pressure Fallback
Travel Cutoff Hi
Travel Cutoff Lo
:Pressure Cutoff Open
:Pressure Cutoff Closed
:Pressure Range Hi
:Pressure Range Lo
Instrument
Tag Description
Pressure Units
Temperature Units
Travel Units
Length Units
Area Units
Spring Rate Units
:Relay Type
:Zero Power Condition
:Maximum Supply Pressure
Calibration Person
Calibration Location
Calibration Date
:Last Calibration Type
Valve and Actuator
Valve
Trim
Actuator
Reference
Actuator
Actuator Manufacturer
Actuator Model Number
:Actuator Style
Actuator Serial Number
:Actuator Size
Actuator Fail Action
:Feedback Connection
:Travel Sensor Motion
:Lever Style
:Lever Arm Length
:Effective Area
:Air
:Upper Bench Set
:Lower Bench Set
:Nominal Supply Pressure
:Spring Rate
Instruction Manual
D103412X012
Pressure Tuning
:Pressure Tuning Set
:Pressure Proportional Gain
:Pressure MLFB Gain
:Pressure Integral Gain
:Pressure Integral Dead Zone
:Pressure Integral Limit Hi
:Pressure Integral Limit Lo
Alerts (See facing page)
Elect Alerts
Configuration Alerts
Sensor Alerts
Environment Alerts
Travel Alerts
Prox Alerts
Travel History Alerts
Performance Alerts
PlantWeb Alert Enable
PlantWeb Alert Reporting
Valve
Valve Manufacturer
Valve Model Number
Valve Serial Number
Valve Style
:Valve Size
:Valve Class
:Rated Travel
:Actual Travel
:Shaft Stem Diameter
:Packing Type
:Inlet Pressure
:Outlet Pressure
Trim
:Seat Type
:Leak Class
:Port Diameter
:Port Type
:Flow Direction
:Push Down To
:Flow Tends To
:Unbalanced Area
Need help?
Do you have a question about the FIELDVUE DVC6200f and is the answer not in the manual?
Questions and answers