Module Base; I/P Converter Assembly; Relay; Terminal Box - Fisher FIELDVUE DVC6200f Instruction Manual

Digital valve controller for foundation fieldbus
Table of Contents

Advertisement

Instruction Manual
D103412X012
Figure 8‐1. Terminal Box of Natural Gas Certified
FIELDVUE DVC6200f Digital Valve Controller
WIRING CONNECTOR
GAS‐BLOCKING
PRESS‐FIT ADAPTOR
W9923‐1
Key
Description

Module Base

(see figure 8‐2 and 8‐4)
DVC6200f and DVC6205f
(6)
  2
Module Base
(6)
 11
Drive Screw
(2 req'd)
(1)
 12
O‐ring
(6)
 19
Label, Shield Assembly
(6)
61
Pipe Plug, hex socket
(3 req'd)
243
Slotted Pin (flame arrestor)

I/P Converter Assembly

(see figure 8‐2 and 8‐4)
DVC6200f and DVC6205f
 23
Cap Screw, hex socket, SST
(1)(3)(5)
 39* O‐ring
(5)
 41
I/P Converter
(5)(8)
169
Shroud
(not shown, see figure 7‐4)
(1)(5)
210* Boot, nitrile
(2 req'd) (see figure 7‐4)
(1)(3)(5)
231* Seal Screen
*Recommended spare
1. Available in the Elastomer Spare Parts Kit
2. Available in the Small Hardware Spare Parts Kit
3. Available in the Seal Screen Kit
4. Available in the Terminal Box Kit
5. Available in the I/P Converter Kit
6. Available in the Spare Module Base Assembly Kit
8. Available in the Spare Shroud Kit
Part Number
(6)
(3 req'd)
(2)(8)
(4 req'd)
Key
Description
Relay (see figure 8‐2 and 8‐4)
DVC6200f and DVC6205f
24* Relay Assembly, (includes shroud, relay seal, mounting screws)
  Standard (nitrile elastomers)
  Standard Bleed
  Housing A (used for GX actuator)
   Single‐/acting direct (relay C)
   Single‐acting reverse (relay B)
  Housing B (used for all actuators except GX)
   Single‐acting direct (relay C)
   Double‐acting (relay A)
   Single‐acting reverse (relay B)
  Low Bleed
  Housing A (used for GX actuator)
   Single‐acting direct (relay C)
   Single‐acting reverse (relay B)
  Housing B (used for all actuators except G)
   Single‐acting direct (relay C)
   Double‐acting (relay A)
   Single‐acting reverse (relay B)
  Extreme Temperature option (fluorosilicone elastomers)
  Standard Bleed
    Single‐acting direct (relay C)
    Double‐acting (relay A)
    Single‐acting reverse (relay B)
  Low Bleed
    Single‐acting direct (relay C)
    Double‐acting (relay A)
    Single‐acting reverse (relay B)
Loop Connections Terminal Box
(see figure 8‐2 and 8‐4)
DVC6200f and DVC6205f
  4
Terminal Box Cap
(1)(4)
 34* O‐ring
(1)(4)
 36* O‐ring
 58
Set Screw, hex socket, SST
 72
Cap Screw, hex socket, SST
164
Terminal Box Assembly
Parts
July 2013
Part Number
38B5786X182
38B5786X172
38B5786X132
38B5786X052
38B5786X092
38B5786X202
38B5786X192
38B5786X152
38B5786X072
38B5786X112
38B5786X142
38B5786X032
38B5786X102
38B5786X162
38B5786X082
38B5786X122
(2)
(2)
251

Hide quick links:

Advertisement

Table of Contents
loading