Example For Configuring The Interconnection Of Ftp Servers And Devices In And Out Of The Hgmp Cluster (In Non-Nat Mode) - Huawei Quidway S5700 Series Configuration Manual - Network Management

Hide thumbs Also See for Quidway S5700 Series:
Table of Contents

Advertisement

Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management
l
l
3.6.3 Example for Configuring the Interconnection of FTP Servers
and Devices in and out of the HGMP Cluster (in Non-NAT Mode)
Networking Requirements
As shown in
the administrator switch of the cluster and other switches are member switches. The member ID
of Member-2 is 2 and the member ID of Member-3 is 3.
Issue 01 (2011-10-26)
return
Configuration file of Member-2.
#
sysname Member-2
#
FTP server enable
#
vlan batch 10
#
cluster enable
ntdp enable
ntdp hop 5
ntdp timer 10
ndp enable
#
interface Vlanif10
#
interface GigabitEthernet0/0/1
port link-type trunk
port trunk allow-pass vlan 10
ntdp enable
ndp enable
#
cluster
mngvlanid 10
administrator-address 0001-0001-0001 name HUAWEI
#
return
Configuration file of Member-3.
#
sysname Member-3
#
vlan batch 10
#
cluster enable
ntdp enable
ntdp hop 5
ntdp timer 10
ndp enable
#
interface Vlanif10
#
interface GigabitEthernet0/0/1
port link-type trunk
port trunk allow-pass vlan 10
ntdp enable
ndp enable
#
cluster
mngvlanid 10
administrator-address 0001-0001-0001 name HUAWEI
#
return
Figure
3-5, all the Layer 2 switches belong to the same cluster. Administrator-1 is
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
3 HGMP Configuration
128

Advertisement

Table of Contents
loading

Table of Contents