Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management
Step 4 Run:
set constant-ifindex subinterface { dense-mode | sparse-mode }
The memory distribution mode for the sub-interface index is set.
When a sub-interface is created, the system generates an index image file for the sub-interface
in the memory in a specified mode. You may use various sub-interface numbering modes, such
as the continuous mode or the discontinuous mode. In real-world situations, one of the following
distribution modes can be used as needed:
l Sparse mode: applies to discontinuous sub-interface numbering.
l Dense mode: applies to continuous sub-interface numbering.
----End
1.4.7 Checking the Configuration
After SNMPv3 functions are configured, you can view the SNMPv3 configurations.
Prerequisite
The configurations of basic SNMPv3 functions are complete.
Procedure
l
l
l
l
l
l
l
l
l
----End
1.5 SNMP Configuration Examples
This section provides several configuration examples of SNMP. The configuration roadmap in
the examples will help you understand the configuration procedures. Each configuration
example provides information about the networking requirements, configuration notes, and
configuration roadmap.
Issue 01 (2011-10-26)
Run the display snmp-agent usm-user [ engineid engineid | group group-name |
username user-name ]
Run the display snmp-agent sys-info version command to check the enabled SNMP
version.
Run the display acl acl-number command to check the rules in the specified ACL.
Run the display snmp-agent mib-view command to check the MIB view.
Run the display snmp-agent sys-info contact command to check the equipment
administrator's contact information.
Run the display snmp-agent sys-info location command to check the location of the
device.
Run the display snmp-agent target-host command to check the information about the
target host.
Run the display snmp-agent extend error-code status command to check whether the
SNMP extended error code feature is enabled.
Run the display constant-ifindex configuration command to check whether the constant
interface index function is enabled and the relevant configuration information.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
*
command to check user information.
1 SNMP Configuration
34