l To configure the interval for sending the test packets, run the interval seconds interval
l To configure the percentage of the failed NQA test, run the fail-percent percent command.
l To configure the NQA test packets to be sent without searching the routing table, run the
Step 6 Run:
start
The NQA test is started.
Select the start mode as required because the start command has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
l To perform the NQA test after a certain delay period, run the start delay { seconds second
----End

6.5.3 Checking the Configuration

After configuring the ICMP test, you can view the test result.
Prerequisite
The configurations of the ICMP Test function are complete.
Context
Procedure
Step 1 Run the display nqa results [ test-instance admin-name test-name ] command to view the test
results on the NQA client.
----End
Issue 01 (2011-10-26)
command.
interval seconds equals the "-m" option in the ping command.
sendpacket passroute command.
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } } ]
command.
The test instance is started immediately.
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } } ] command.
The test instance is started at a specified time.
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } } ] command.
The test instance is started after a certain delay.
NOTE
NQA test results cannot be displayed automatically on a terminal. You must run the display nqa results
command to view test results. By the default, the command output contains the records about only the last
five test results.