l To configure the FTP source port number, run the source-port port-numbercommand.
l To configure the FTP destination port number, run the destination-port port-number
l To configure the NQA test packet to be sent without searching the routing table, run the
Step 6 Run:
ftp-operation get
The FTP operation type is set to Get.
By default, the FTP operation type is Get.
Step 7 Run:
ftp-username name
The FTP user name is configured.
Step 8 Run:
ftp-password password
The FTP password used during the login is configured.
Step 9 Run:
ftp-filename file-name
The name of the file to be downloaded is configured.
Step 10 Run:
start
The NQA test is started.
Select the start mode as required because the start command has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
l To perform the NQA test after a certain delay period, run the start delay { seconds second
----End

6.6.3 Checking the Configuration

After configuring the FTP download test, you can view the test result.
Issue 01 (2011-10-26)
command.
sendpacket passroute command.
NOTE
During the FTP test, select a file with a relatively small size for the test. If the file is large, the test may fail
because of timeout.
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } } ]
command.
The test instance is started immediately.
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } } ] command.
The test instance is started at a specified time.
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } } ] command.
The test instance is started after a certain delay.