This part describes how to set a PWE3 trace test parameters for a multi-hop PW.
Context
Do as follows on the NQA client:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
nqa test-instance admin-name test-name
An NQA test instance is created and the test instance view is displayed.
Step 3 Run:
test-type pwe3trace
The test type is set to PWE3 Trace.
Step 4 (Optional) Run:
vc-type ldp
The method of setting up a PW is configured.
Step 5 (Optional) Run:
local-pw-type { local-pw-type | ip-interworking }
The type of the local PW is configured. By default, the type is Ethernet.
Step 6 (Optional) Run:
label-type { control-word | label-alert | normal}
The type of the PW label is configured.
Issue 01 (2011-10-26)
Data
Type of the PW
(Optional) Response mode of the Echo packets, LSP EXP, maximum hops, number
of probes, TTL value, and timeout period of the packets
Type and number of the interface connected with the CE
Start mode and end mode of the test
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
317