Huawei Quidway S5700 Series Configuration Manual - Network Management page 290

Hide thumbs Also See for Quidway S5700 Series:
Table of Contents

Advertisement

Quidway S5700 Series Ethernet Switches
Configuration Guide - Network Management
Step 3 Run:
test-type snmp
The test type is set to SNMP Query.
Step 4 Run:
destination-address ipv4 ip-address
The destination IP address, that is, the IP address of the SNMP agent, is configured.
Step 5 (Optional) Perform the following as required to configure other parameters for the SNMP test
( For detailed parameter configurations, see the chapter
Parameters
l To configure the VPN instance to be tested, run the vpn-instance vpn-instance-name
l To configure the source IP address, run the source-address ipv4 ip-address command.
l To configure the source port number, run the source-port port-numbercommand.
l To configure the interval for sending test packets, run the interval seconds interval
l To configure the percentage of the failed NQA tests, run the fail-percent percent command.
l To configure the NQA test packets to be sent without searching the routing table, run the
Step 6 Run:
start
The NQA test is started.
Select the start mode as required because the start command has several forms.
l To perform the NQA test immediately, run the start now [ end { at [ yyyy/mm/dd ]
l To perform the NQA test at the specified time, run the start at [ yyyy/mm/dd ] hh:mm:ss
l To perform the NQA test after a certain delay period, run the start delay { seconds second
----End
Issue 01 (2011-10-26)
NOTE
The SNMP function must be enabled on the destination host; otherwise, the destination host fails to receive
Echo packets.
):
command.
NOTE
Only S5700EI and S5700HI support the vpn-instance command.
command.
sendpacket passroute command.
hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime { seconds second | hh:mm:ss } } ]
command.
The test instance is started immediately.
[ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } | lifetime
{ seconds second | hh:mm:ss } } ] command.
The test instance is started at a specified time.
| hh:mm:ss } [ end { at [ yyyy/mm/dd ] hh:mm:ss | delay { seconds second | hh:mm:ss } |
lifetime { seconds second | hh:mm:ss } } ] command.
The test instance is started after a certain delay.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
6 NQA Configuration
Configuring Universal NQA Test
279