1 Installation

1
Installation
1.1

Clearance distances for mounting

The inverters can be mounted adjacent to each other. If they are mounted on top of
each other, however, a clearance of 100 mm has to be observed.
Fig. 1-1
1.2

Mounting dimensions

H
W
Fig. 1-2
4
15 mm
0 mm
Clearance distances for mounting
Frame
Drilling Dimensions
Size
mm (Inch)
A
160 (6.30)
B
174 (6.85)
C
204 (8.03)
Mounting dimensions
100 mm
...
H
W
mm (Inch)
138 (5.43)
174 (6.85)
Issue 04/04
15 mm
Tightening Torque
Bolts
Nm (ibf.in)
2xM4
2.5 (22.12)
4xM4
4xM4