24.4 UM Configuration—[5-4] System Parameters—Parameters
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Outside Transfer Sequence—Call Transfer to Outside Answer Mode
Specifies the answering method the system uses to detect whether the destination party has answered the
transferred CO line call.
Default
Guidance
Value Range
Guidance: The system plays the following guidance before connecting the line to the destination party: "You
have a call. To answer the call, press [1]. Otherwise, press [2] and hang up." If the destination party presses
"1", he or she will be able to answer the transferred CO line call. The system continues playing this guidance
for the time specified in
Parameters/MSW Notification. If the transferred party does not answer the call within this time, the system
considers it as a No Answer call.
Analyze: The system monitors the status of the CO line, recognizes that the destination party goes off-hook,
and connects the line.
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Feature Manual References
20.1.16 Unified Messaging—Call Transfer to Outside
Trunk Group (1–96)—Trunk Group No.
Specifies a trunk group for making settings for EFA Transfer, Caller ID Callback, and Outside Line Access
Sequence for Caller ID Callback. Selecting different trunk groups from this drop-down list allows settings to be
made for each trunk group.
Default
1
Value Range
1–96
Maintenance Console Location
24.4 UM Configuration—[5-4] System Parameters—Parameters
Trunk Group (1–96)—EFA Transfer
Specifies whether or not the system uses EFA (External Feature Access) when transferring incoming CO line
calls to another CO line. If set to "Enable", the system transfers incoming CO line calls to another CO line
according to "EFA Transfer Sequence" specified in "Transfer to Outside". If set to "Disable", the system
transfers incoming CO line calls to another CO line according to
Transfer to Outside Sequence (Up to 16 digits / [0-9 * # D F R T , ; N]) specified in Transfer to Outside.