27.2.1 Router Configuration—Setup—[1-2-1] WAN—Connection Settings
Value Range
1–3600 s
Maintenance Console Location
27.2.1 Router Configuration—Setup—[1-2-1] WAN—Connection Settings
LCP ECHO—LCP Echo Retries
Specifies the number of times that the PBX tries to get a response to an LCP echo request before the PPPoE
connection is considered inactive.
If LCP ECHO is not selected for 27.2.1 Router Configuration—Setup—[1-2-1] WAN—Connection
Settings—PPPoE —
Default
5
Value Range
1–255
Maintenance Console Location
27.2.1 Router Configuration—Setup—[1-2-1] WAN—Connection Settings
LCP ECHO—PPPoE Recovery Time
Specifies the number of times that the PBX is judged to be recovered after the PPPoE connection has been
re-established.
If LCP ECHO is not selected for 27.2.1 Router Configuration—Setup—[1-2-1] WAN—Connection
Settings—PPPoE —
Default
8
Value Range
1–255
Maintenance Console Location
27.2.1 Router Configuration—Setup—[1-2-1] WAN—Connection Settings
TCP MSS
Selects the setting method of the TCP MSS (Maximum Segment Size) value.
This function is only available for IPv4 packets.
Auto: MTU-40 is specified.
Fixed: Specifies the TCP MSS Value.
If Auto is selected, MTU-40 is specified. However if MTU is smaller than MRU, MRU-40 is specified.
Note
MTU: Maximum Transmission Unit, MRU: Maximum Receive Unit
1110
PC Programming Manual
PPP Keep-Alive, this item is grayed out.
PPP Keep-Alive, this item is grayed out.