"40" (P0505) ISC VALVE CIRCUIT MALFUNCTION
DETECTED CONDITION
When the ISC operation voltage
40
remains at 1.0 V or lower continuously
(P0505)
for 2 sec. or longer.
Idle speed is higher than the normal
condition.
ECM
ISC
INSPECTION
Step 1
1) Turn the ignition switch OFF.
2) Remove the right leg shield. (#5-6)
3) Check the ISC valve coupler 1 for loose or poor contacts.
If OK, then check the ISC valve resistance.
4) Disconnect the ISC valve coupler.
5) Measure the ISC valve resistance.
! ISC valve resistance: Approx. 35 Ω

Front brake

switch
Y/R
Y/R
O
O
ISC valve
Y/G
Y/G
(Terminal – Terminal)
POSSIBLE CAUSE
• ISC valve circuit open or shorted to ground.
• ISC valve malfunction.
• ECM malfunction.
R/W
R/W

Battery

cut off
relay
R
R
1
1
FL125SDW
To regulator/rectifier

Fuse

(15A)
Battery
8-70