8-49
FL125SDW
7) Disconnect the ECM coupler.
8) Check the continuity between R wire A and terminal 9.
! IAP sensor lead wire continuity: Continuity ())
$ 09900-25008: Multi-circuit tester set
09900-25009: Needle pointed probe set
* Tester knob indication: Continuity test ())
%
When using the multi-circuit tester, do not strongly
touch the terminal of the ECM coupler with a needle
pointed tester probe to prevent the terminal damage
or terminal bend.
Is the continuity OK?
YES
Go to Step 2.
NO
R wire open, or G/B wire shorted to ground
9) After repairing the trouble, clear the DTC using SDS tool.
(#8-39)
1
ECM coupler (Harness side)
!