<Continuation of [Clamp]>
Function
F4SN
Setting for number of block
when block step is used
AF2
Selection of pneumatic
pressure two-step clamp
OPR
Prohibition of sewing data
reading when clamp is
raised
OST
Prohibition of operation
(sewing, JOG) when clamp
is raised
CHK
Cassette jig function
ON/OFF
CSN
Cassette jig sensor
ON/OFF
CSY
Cassette jig sensor
ON/OFF during sewing
1ST
Do not use

4.Area limit

(*
When the value of the sewing area limit is changed or the limit setting is deactivated,
note the collision and take care safely.
Also when using it outside the range where the mechanism can be operated, it can not
assume the responsibility for all problems caused by it.
Function
ALC
Area limit cancel ON/OFF
XL
[X axis left side] area limit
setting
XR
[X axis right side] area limit
setting
YU
[Y axis rear side] area limit
setting
YD
[Y axis front side] area limit
setting
Unit
Setting range
-
1 ~ 4
The pneumatic presser two-step clamp is set.
-
OF
ON
Reading the sewing data is prohibited by the state of the clamp.
-
OF
ON
Prohibition of operation (sewing, JOG) when clamp is raised
-
OF
ON
Change the cassette jig function effect.
OF
-
ON
Change the cassette jig sensor effect.
OF
ON
Change the cassette jig sensor effect. (During sewing)
OF
ON
×100
0 ~ 100
ms
Unit
Setting range
Change the sewing area limit effect.
-
OF
ON
×0.1
1 ~ 65535
mm
×0.1
1 ~ 65535
mm
×0.1
1 ~ 65535
mm
×0.1
1 ~ 65535
mm
When set the OFB=[4], the clamp blocks of this value executes
step movement.
1:Block1,
2:Block1+2,
3:Block1+2+3,
4:Block1+2+3+4
(Block1=OF1,OF2 Block2=OF3,OF4 Block3=OF5,OF6
Block4=OF7,OF8).
Use the normal clamp.
Use the pneumatic pressure two-step clamp (Option). In this
case, all of the specifications of the other clamps are invalidated.
sewing data can be read regardless of the state of clamp.
Sewing data read is prohibited when the clamp is raised.
Operation (sewing, JOG) is prohibited when clamp is raised.
Starts even if the clamp is not down position.
Cassette jig function is invalid.
Cassette jig function is valid.
Cassette jig sensor is invalid.
Cassette jig sensor is valid.
Cassette jig sensor is invalid during sewing.
When the cassette jig sensor is not detected during sewing,
the machine is not stopped automatic.
Cassette jig sensor is valid during sewing.
When the cassette jig sensor is not detected during sewing,
the machine is stopped automatic.
Do not use
)
The stitching area limit is validated.
(XL,XR,YU,YD setting is reflected)
The stitching area limit is invalidated. (The stitching area limit is
canceled.) Please use this setting with attention.
The numerical value of the X motor left side area limit can be
setting in the software. The default setting for the X motor left
side area limit differs according to the model. Do not reduce this
value much. Error occurs.
The numerical value of the X motor right side area limit can be
setting in the software. The default setting for the X motor right
side area limit differs according to the model. Do not reduce this
value much. Error occurs.
The numerical value of the Y motor rear side area limit can be
setting in the software. The default setting for the Y motor rear
side area limit differs according to the model. Do not reduce this
value much. Error occurs.
The numerical value of the Y motor front side area limit can be
setting in the software. The default setting for the Y motor front
side area limit differs according to the model. Do not reduce this
value much. Error occurs.
[16] - 4